Building a NOC Dashboard
📊 Module 3: Real-Time Telemetry
Building a NOC Dashboard
A Network Operations Center (NOC) dashboard is the primary interface for grid operators. It must present thousands of data points in a way that enables rapid situational awareness and decision-making.
Dashboard Design Principles
1. Overview First, Details on Demand
The landing view should show the entire grid at a glance: total generation, total load, frequency, and a geographic or schematic overview with color-coded device status. Operators should be able to drill down to individual devices with a single click.
2. The 10-Second Rule
An operator should be able to assess the grid's overall health within 10 seconds of looking at the dashboard. This means:
- KPI strip at the top: Total MW, frequency, active alarms, system reserve margin
- Traffic light indicators: Green (normal), yellow (caution), red (critical) for each zone or asset group
- Alarm banner: Scrolling or stacked display of unacknowledged alarms
3. Consistent Color Coding
| Color | Meaning |
|---|---|
| Green | Normal / Online / Healthy |
| Yellow | Warning / Degraded |
| Orange | Major alarm / Approaching limit |
| Red | Critical / Tripped / Offline |
| Gray | Unknown / No communication |
| Blue | Maintenance / Disabled |
Essential Dashboard Components
System Overview Bar
Total Generation: 847 MW | Total Load: 832 MW | Frequency: 50.01 Hz | Reserve: 15 MW (1.8%)
Active Alarms: 3 Critical, 7 Major, 12 Minor | Data Quality: 99.2%Geographic Map / Single Line Diagram
A schematic representation of the grid showing:
- Substations as nodes with voltage and loading
- Transmission lines with power flow direction and magnitude
- Generator symbols with MW output and status
- Color-coding based on loading percentage
Alarm List
A filterable, sortable table showing:
- Timestamp, priority, device, description, value, status (active/acknowledged/cleared)
- Click to navigate to the affected device
- Bulk acknowledge capability
Trend Charts
Real-time strip charts (last 1-4 hours) for key variables:
- Frequency trend with +/- 0.2 Hz band highlighted
- Total generation and load stacked area chart
- Battery SOC for all BESS units
- Solar generation vs. forecast
Device Table
A tabular view of all monitored devices with:
- Name, type, location, communication status, last update timestamp
- Key operational values (power, SOC, temperature)
- Sortable by any column, filterable by type/status/location
Real-Time Update Strategy
Grid dashboards must update in near real-time without overwhelming the browser:
- WebSocket push for alarm state changes and critical values (< 1 second latency)
- Polling every 5-10 seconds for bulk telemetry updates
- Progressive loading: Load the overview first, then populate detail panels asynchronously
- Stale data indicators: Show a "last updated" timestamp per device; highlight devices with stale data (> 30 seconds old)
Responsive Design for Control Rooms
Control room displays are typically large-format (55" to 100" video walls) at viewing distances of 3-5 meters. Design considerations:
- Minimum font size: 16px for primary values, 12px for secondary
- High contrast: Dark background with bright indicators (reduces eye strain during 12-hour shifts)
- No scrolling on the main view: Everything fits on one screen
- Keyboard shortcuts: F1 for alarm acknowledge, F5 for refresh, arrow keys for navigation
Log in to track your progress and earn certifications.