🌱 Carbon & Compliance — 6.3
Developer HubModule 6: Carbon & Compliance6.3
Reading15 min

Scope 2/3 Accounting for Energy

🌱 Module 6: Carbon & Compliance

Scope 2/3 Accounting for Energy

The Greenhouse Gas (GHG) Protocol classifies emissions into three scopes. For energy companies and large consumers, Scope 2 and Scope 3 are the most significant and complex to account for.

The Three Scopes

  • Scope 1: Direct emissions from owned or controlled sources (e.g., on-site generators, company vehicles, fugitive emissions from gas equipment)
  • Scope 2: Indirect emissions from purchased electricity, steam, heating, and cooling
  • Scope 3: All other indirect emissions in the value chain (upstream and downstream)

Scope 2: Purchased Electricity

Scope 2 has two accounting methods:

Location-based method: Uses the average grid emission factor for the location where electricity is consumed.

Scope 2 (location) = Electricity consumed (MWh) × Grid average EF (tCO2/MWh)

Example: A Dubai data center consuming 50,000 MWh/year on a grid with EF = 0.45 tCO2/MWh:

Scope 2 = 50,000 × 0.45 = 22,500 tCO2

Market-based method: Uses emission factors from contractual instruments (RECs, PPAs, GOs).

  • Bundled PPA (Power Purchase Agreement): A direct contract with a specific renewable generator. EF = 0 for the contracted volume.
  • Unbundled RECs (Renewable Energy Certificates): Purchased separately from the physical electricity. EF = 0 for the volume covered by RECs.
  • Residual mix: For uncovered electricity, use the residual grid mix (excluding electricity already claimed by others' RECs).
If 30,000 MWh covered by solar PPA and 20,000 MWh from grid:
  Scope 2 (market) = (30,000 × 0) + (20,000 × 0.45) = 9,000 tCO2

24/7 Carbon-Free Energy (CFE)

Traditional annual matching (buying enough RECs to cover total annual consumption) does not mean the facility was actually powered by clean energy at every hour. 24/7 CFE requires hourly matching:

For each hour h:
  CFE_score_h = min(1, Clean_supply_h / Total_demand_h)

Annual CFE% = Average(CFE_score_h) for all hours in the year

Google, Microsoft, and other hyperscalers are pursuing 24/7 CFE by 2030. This requires:

  • Time-matched renewable procurement (hourly PPAs)
  • Geographically matched procurement (same grid zone)
  • Storage to shift clean energy to hours when renewables are unavailable

Scope 3 for Energy Companies

Scope 3 categories most relevant to energy:

CategoryDescriptionExample
Cat 1: Purchased goodsEmissions from manufacturing equipmentSolar panel manufacturing
Cat 2: Capital goodsEmissions from building infrastructureConstructing a substation
Cat 3: Fuel/energyUpstream emissions from fuelNatural gas extraction and transport
Cat 8: Upstream leased assetsEmissions from leased facilitiesLeased data center space
Cat 11: Use of sold productsEmissions from energy sold to customersCustomer electricity consumption
Cat 13: Downstream leased assetsEmissions from assets leased to othersLeased generator running on diesel

Scope 3 Category 8: Upstream Leased Assets

For companies leasing space in data centers (common for cloud and CDN providers like Akamai):

Scope 3 Cat 8 = Leased floor area / Total floor area × Total facility emissions

Or, for IT equipment-based allocation:

Scope 3 Cat 8 = Leased IT load (kW) / Total IT load (kW) × Total facility emissions × PUE

Verification and Audit Trail

Carbon accounting requires an auditable trail:

  1. Metered data: Electricity consumption from revenue-grade meters (not estimates)
  2. Emission factors: Documented source and version (e.g., "eGRID 2024, subregion SRSO")
  3. Contractual instruments: Copies of PPAs, REC certificates with serial numbers, retirement records
  4. Calculations: Transparent methodology with formulas and intermediate results
  5. Third-party verification: Assurance statement from an accredited verifier (ISO 14064-3)

EnergyAtIt's carbon accounting service maintains a complete audit trail with hash-chained attestation (see Lesson 6.3) for tamper-evidence.

Log in to track your progress and earn certifications.